EasyManua.ls Logo

ABB PFEA 113 - Page 61

ABB PFEA 113
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tension Electronics PFEA113, User Manual
Section 3.12.7 Setting Analog Outputs (AO1-AO6)
3BSE029382R0101 Rev C 3-29
The following can be selected in:
1. Menu SystemDefinition
OneRoll
TwoRolls
SegmentedRoll
2. Menu ObjectType
Roll1 (StandardRoll, SingleSideA or SingleSideB
Roll2 (StandardRoll, SingleSideC or SingleSideD
Segmented roll (OneInput, TwoInputs, ThreeInputs, FourInputs)
Based on what has been selected in SystemDefinition and ObjectType, the following
alternatives of “ConnectSignals” can be used:
System definition Object Type AO1 - AO6 can be connected to ....
One roll Standard roll A, B, A+B, A-B
Single side TensionRoll 1
Two rolls Roll 1: standard roll
Roll 2: standard roll
A, B, A+B, A-B
C, D, C+D, C-D
Roll 1: single side
Roll 2: single side
TensionRoll 1
TensionRoll 2
Roll 1: standard roll
Roll 2: single side
A, B, A+B, A-B
TensionRoll 2
Roll 1: single side
Roll 2: standard roll
TensionRoll 1
C, D, C+D, C-D
Segmented roll One input A
A+AI1
A+AI1+AI2
A-AI2
AI1-AI2
Two inputs A, B
A+B
A-B
A+B+AI1
A+B+AI1+AI2
B-AI2
AI1-AI2
Three inputs A, B, C
A+B+C
A-C
A+B+C+AI1
A+B+C+AI1+AI2
C-AI2
AI1-AI2
Four inputs A, B, C, D
A+B+C+D
A-D
A+B+C+D+AI1
A to D+AI1+AI2 (A+B+C+D+AI1+AI2)
D-AI2
AI1-AI2

Table of Contents