Tension Electronics PFEA113, User Manual
Section 3.12.7 Setting Analog Outputs (AO1-AO6)
3BSE029382R0101 Rev C 3-29
The following can be selected in:
1. Menu SystemDefinition
– OneRoll
– TwoRolls
– SegmentedRoll
2. Menu ObjectType
– Roll1 (StandardRoll, SingleSideA or SingleSideB
– Roll2 (StandardRoll, SingleSideC or SingleSideD
– Segmented roll (OneInput, TwoInputs, ThreeInputs, FourInputs)
Based on what has been selected in SystemDefinition and ObjectType, the following
alternatives of “ConnectSignals” can be used:
System definition Object Type AO1 - AO6 can be connected to ....
One roll Standard roll A, B, A+B, A-B
Single side TensionRoll 1
Two rolls Roll 1: standard roll
Roll 2: standard roll
A, B, A+B, A-B
C, D, C+D, C-D
Roll 1: single side
Roll 2: single side
TensionRoll 1
TensionRoll 2
Roll 1: standard roll
Roll 2: single side
A, B, A+B, A-B
TensionRoll 2
Roll 1: single side
Roll 2: standard roll
TensionRoll 1
C, D, C+D, C-D
Segmented roll One input A
A+AI1
A+AI1+AI2
A-AI2
AI1-AI2
Two inputs A, B
A+B
A-B
A+B+AI1
A+B+AI1+AI2
B-AI2
AI1-AI2
Three inputs A, B, C
A+B+C
A-C
A+B+C+AI1
A+B+C+AI1+AI2
C-AI2
AI1-AI2
Four inputs A, B, C, D
A+B+C+D
A-D
A+B+C+D+AI1
A to D+AI1+AI2 (A+B+C+D+AI1+AI2)
D-AI2
AI1-AI2