Table 949: RDRE Non-group channel settings
Parameter Values
(Range)
Unit Step Default Description
Operation
1=on
5=off
1 1=on Analog chan-
nel is enabled
or disabled
Channel se-
lection
0=Disabled
1=Io
2=IL1
3=IL2
4=IL3
5=IoB
6=IL1B
7=IL2B
8=IL3B
9=Uo
10=U1
11=U2
12=U3
13=UoB
14=U1B
17=CIo
18=SI1
1
19=SI2
1
20=SU0
21=SU1
1
22=SU2
1
23=CIoB
24=SI1B
1
25=SI2B
1
52=U1C
0 0=Disabled Select the sig-
nal to be re-
corded by
this channel.
Applicable
values for this
parameter are
product var-
iant depend-
ent. Every
product var-
iant includes
only the val-
ues that are
applicable to
that particu-
lar variant
Table continues on the next page
1
Recordable values are available only in trend mode. In waveform mode, samples for this signal
type are constant zeroes. However, these signal types can be used to trigger the recorder on
limit violations of the corresponding analog channel.
1MRS757644 H Measurement functions
620 series
Technical Manual
973