MX2800 STS-1 User Manual Configuration, Section 3
System Management
61204659L1-1A 3-25
Power Supply Alarm Traps
Power Supply Alarm trap messages are sent for the reasons provided in Table 3-6.
MIB II Standard Alarm Traps
MIB II Standard Alarm trap messages are sent for the reasons provided in Table 3-7.
Read Community Name
Enter the authentication strings used for SNMP management. Match the MX2800 STS-1 to the SNMP
manager for read privileges.
Write Community Name
Enter the authentication strings used for SNMP management. Match the MX2800 STS-1 to the SNMP
manager for write privileges.
Table 3-6. Power Supply Alarm Traps
Trap If enabled, the unit issues a trap when...
Card Removed The power supply card has been removed
Malfunction The power supply card is no longer working and the unit has switched to the
backup power supply or battery backup
Card Failure The power supply card has failed
Power Low The power supply’s output level is abnormally low
Bat. Backup Active Battery charger has lost its AC source and is now running off the battery backup
Battery Low The battery backup has reached a critical energy point at which it may be unable
to supply the unit with sufficient power to maintain operation
Temperature High The power supply card is getting too hot
Temperature Crit The power supply card temperature is so high that it may suffer damage
Table 3-7. MIB II Standard Alarm Traps
Trap If enabled, the unit issues a trap when...
Cold Start The unit is first powered up
Link Up The STS-1 is up with no alarms
Link Down The STS-1 is in alarm
Auth. Failure An unauthorized attempt has been made to access the unit