9-26 61204659L1-1A
Section 9, Transaction Language 1 (TL1) MX2800 STS-1 User Manual
TL1 Error Codes
EQPT Data Dictionary
Table 9-9 contains entries that are used to edit or retrieve options for the equipment portion of the
MX2800. When performing TL1 edit commands from this table, the value of rr should be EQPT, and the
<aid> value should be the following:
401 - Generic
Table 9-9. TL1 Editing Data Dictionary for EQPT
Keyword Type Domain Description
CLOCKSTATUSRLY Y/N Y or [N] Provisions alarm relay response for the
Clock Status Changed alarm
Yes (Y) - enables alarm relay response
No (N) - disables alarm relay response
CLOCKPRIRLY Y/N Y or [N] Provisions alarm relay response for the
Primary Reference Failure alarm
Yes (Y) - enables alarm relay response
No (N) - disables alarm relay response
CLOCKSECRLY Y/N Y or [N] Provisions alarm relay response for the
Secondary Reference Failure alarm
Yes (Y) - enables alarm relay response
No (N) - disables alarm relay response
CLOCKLOARLY Y/N Y or [N] Provisions alarm relay response for the
Clock Loss of Activity alarm
Yes (Y) - enables alarm relay response
No (N) - disables alarm relay response
DIAGBERCLEARCOUNT Y/N Y or [N] Clears BERT count
Yes (Y) - clears the BERT count
No (N) - does not clear the BERT count
DIAGBERTCOUNT INT 0, 1, 2, ..., N Error count
DIAGBERTSYNC ENUM One of the following:
•NOSYNC
SYNC
Identifies state of Pattern Synchronization
NOSYNC - there is no pattern sync
SYNC - pattern sync is available