4.
Clean the supply module from any DEF leakage.
5.
Install wiring and tubing supports.
3.14.5 Removing the hydraulic connectors
Removing of the supply module is important in order to replace the hydraulic connectors. By removing the
supply module can be made sure that torque wrench can be used and that cleanliness can be guaranteed.
Procedure
1.
Remove the supply module.
2.
Remove the hydraulic connector.
3.14.6 Installing the hydraulic connectors
Procedure
1.
Connect the hydraulic connectors.
2.
Tighten the hydraulic connector to 4,5 ± 0,5 Nm.
3.
Install the supply module.