VLL Service Configuration Commands
Page 226 7210 SAS-X, R6 OS Services Guide
Parameters agi — Specifies the attachment group identifier.
Values 0 — 4294967295
saii-type2
Syntax saii-type2 global-id:node-id:ac-id
no saii-type2
Context config>service>epipe>spoke-sdp>pw-path-id
Description Platforms Supported: 7210 SAS-T and 7210 SAS-R6.
This command configures the source individual attachement identifier (SAII) for an MPLS-TP spoke-
sdp. If this is configured on a spoke-sdp for which vc-switching is also configured, that is, if it is at an
S-PE, then the values must match those of the taii-type2 of the mate spoke-sdp.
Parameters global-id — Specifies the global ID at the source PE or T-PE for the MPLS-TP PW for a spoke-SDP.
Values 0 — 4294967295
node-id — Specifies the node ID at the source PE or T-PE for the MPLS-TP PW for a spoke-SDP.
Values a.b.c.d or 0 — 4294967295
ac-id — Specifies the attachment circuit ID at the source PE or T-PE for the MPLS-TP PW for a
spoke-SDP. If this node is the source of the PW, then the AC ID must be set to a locally unique
value.
Values 1 — 4294967295
taii-type2
Syntax taii-type2 global-id:node-id:ac-id
no taii-type2
Context config>service>epipe>spoke-sdp>pw-path-id
Description Platforms Supported: 7210 SAS-T and 7210 SAS-R6.
This command configures the source individual attachement identifier (SAII) for an MPLS-TP spoke-
sdp. If this is configured on a spoke-sdp for which vc-switching is also configured i.e. it is at an S-PE,
then the values must match those of the taii-type2 of the mate spoke-sdp.
Parameters global-id — Specifies the global ID at the target PE or T-PE for the MPLS-TP PW for a spoke-SDP.
Values 0 — 4294967295
node-id — Specifies the node ID at the target PE or T-PE for the MPLS-TP PW for a spoke-SDP.
Values a.b.c.d or 0 — 4294967295
ac-id — Specifies the attachment circuit ID at the target PE or T-PE for the MPLS-TP PW for a
spoke-SDP. If this node is the source of the PW, then the AC ID must be set to a locally unique