GMPLS
7450 ESS MPLS Guide Page 469
Parameters te-link-id — Specifies the ID of the TE Link.
Values 1 — 4294967295 | te-link-name
te-link-name: 32 character (max) name of the TE Link
shutdown
Syntax [no] shutdown
Context config>router>lmp>peer
Description This comand administratively enables or disables LMP with a given peer.
Default no shutdown
te-link
Syntax [no] te-link te-link-id
Context config>router>lmp
Description This command creates a Traffic Engineering (TE) Link in LMP across a GMPLS UNI. An unsigned
integer TE link ID must be specified when the TE Link is first created. Once the link is created, the
user can configure the link name (i.e. 'link-name te-link-name'). From here, the user can refer to this
TE Link by either the unsigned integer or the ASCII name.
Default no te-link
Parameters te-link-id — Specifies the ID of the TE Link.
Values 1 — 4294967295 | te-link-name
te-link-name: 32 character (max) name of the TE Link
data-bearer
Syntax [no] data-bearer data-bearer-id
Context config>router>lmp>te-link
Description This command creates a data bearer assigned to a TE Link. Only one data bearer may be configured
within a given TE Link.
Default no data-bearer
Parameters data-bearer-id — Specifies the ID of the data bearer.
Values 1 — 4294967295