EasyManuals Logo

Amazone EasySet 2 User Manual

Amazone EasySet 2
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #82 background imageLoading...
Page #82 background image
Commissioning
ZA-V BAG0087.11
01.20
(1) Open-Center hydraulic system with con-
stant flow pump (gear pump) or setting
pump.
Put the system setting screw in position A.
Setting pump: Set the maximum required oil
quantity on the tractor control unit. If the oil
quantity is insufficient, correct functioning of
the implement cannot be ensured.
(2) Load-Sensing hydraulic system (pressure-
and flow-
regulated setting pump) with direct
load sensing pump connection and LS set-
ting pump.
Put the system setting screw in position B.
(3) Load-Sensing hydraulic system with con-
stant flow pump (gear pump).
Put the system setting screw in position B.
(4) Closed-Center hydraulic system with pres-
sure-regulated setting pump.
Put the system setting screw in position B.
Risk of overheating of the hydraulic system:
the Closed-Center hydraulic system is less
suitable for the operation of hydraulic mo-
tors.
Fig. 52

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Amazone EasySet 2 and is the answer not in the manual?

Amazone EasySet 2 Specifications

General IconGeneral
BrandAmazone
ModelEasySet 2
CategorySpreader
LanguageEnglish

Related product manuals