-V BAG0087.11 01.20
Spread rate check while standing still
• It is recommended to perform a spread rate check each time the
fertiliser is changed.
• Perform the spread rate check at a standstill with the spreading
discs removed and the spreading disc drive switched on.
• Perform a test run first in order to ensure for continuous fertiliser
flow.
• Take note of the following values during the rate check:
ο Flow time in s
ο Flow quantity in kg
• Fill the collection bucket as full as possible during the spread
rate check.
8.4.1 Preparations for the spread rate check with the fertiliser chute
1. Remove both spreading discs.
Always install the central bolt for the
spreading disc as protection from water / fertilis-
er, even if the spreading discs are not installed.
2. Hook the fertiliser chute onto the two at-
tachments on the base plate.
3. Put the collection bucket under the fertiliser
chute.
59
60
WARNING
Risk of injury from rotating spread-
ing discs!
Remove both spreading discs before
the spread rate check.
Fig. 52: fertiliser chute attached with holding
clips in parking position.
Before removing from the parking position, press
the fertiliser chute together at the sides.