EasyManuals Logo

Amazone EasySet 2 User Manual

Amazone EasySet 2
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #94 background imageLoading...
Page #94 background image
Adjustments
ZA-V BAG0087.11
01.20
8.4 Spread rate check
See operating manual for the ISOBUS software / Calibrate fertiliser
section.
Alternatively, the spread rate check is:
ZA-V Profis
carried out at the beginning of the spread-
ing process (the calibration factors are
measured while spreading the first 200 kg
of fertiliser).
Machine data menu:
Calibration procedure switch on offline cali-
bration.
Work menu: select Automatic fertiliser cali-
bration
carried out continually throughout the
spreading process (online calibration).
Machine data menu:
Calibration procedure switch on online cali-
bration
ZA-V
performed with the calibration device while
stationary before operation.
The fertiliser flowing out is collected and
weighed
Fig.
57
performed with the fertiliser chute on the left
shutter while standing still before operation.
The fertiliser flowing out is collected and
weighed.
Fig.
58
Always perform a spread rate check
with the fertiliser chute for slug pellets
or fine seeds.