ZA-V BAG0087.11
8.4 Spread rate check
See operating manual for the ISOBUS software / Calibrate fertiliser
section.
Alternatively, the spread rate check is:
• carried out at the beginning of the spread-
ing process (the calibration factors are
measured while spreading the first 200 kg
of fertiliser).
→ Machine data menu:
Calibration procedure switch on offline cali-
bration.
→ Work menu: select Automatic fertiliser cali-
bration
• carried out continually throughout the
spreading process (online calibration).
→ Machine data menu:
Calibration procedure switch on online cali-
bration
• performed with the calibration device while
stationary before operation.
→ The fertiliser flowing out is collected and
weighed
57
• performed with the fertiliser chute on the left
shutter while standing still before operation.
→ The fertiliser flowing out is collected and
weighed.
58
Always perform a spread rate check
with the fertiliser chute for slug pellets
or fine seeds.