MX Series 21
2.1.2 Output
NOTE: All specifications are for AC and DC unless otherwise indicated.
Individual Cabinet Models
MX22.5
MX3 0
MX4 5
Std Controller AC, DC
Pi Controller AC, DC, AC+ DC
Ra n g es ( L-N) :
AC Mo d e
Standard Models: Lo w: 0 - 150 V / High: 0 - 300 V
-333 option: Lo w: 0 - 166 V / High: 0 - 333 V
DC Mo d e
Standard Models: Lo w: 0 - 200 V / High: 0 - 400 V
-333 option: Lo w: 0 - 220 V / High: 0 - 440 V
AC+DC Mod e
Standard Models: Low: 0 - 150 V / High: 0 - 300 V
-333 option: Low: 0 - 166 V / High: 0 - 333 V
DC Offset: Low Vrange: 0 - 150 V
High Vrange: 0 - 220 V (Series II) / High; 0 250 V (Series I).
NOTE:
On MX units with standard controller, only one voltage range is available unless the -R range
change option is installed.
Re s olut ion
AC Mo d e
0.1 V
Re s olut ion
DC Mo d e
0.1 V
Re s olut ion
AC+DC Mo d e
AC: 0.1 V
DC Off s e t :
Series I 0.01 V < 2.5 V
0.1 V 2.5 - 25 V
1 V > 25 V
Series II 0.01 V
Accuracy:
± 0.3 V AC mode
± 1 V DC m o d e
Distortion THD
1
:
(Resistive full load)
MX units shipped before 2009
< 1 % @ 16 - 66 Hz
< 2 % @ 66 - 500 Hz
< 3 % @ > 500 Hz
MX units shipped as of 2009
< 0.5 % @ 16 - 66 Hz
< 1.00 % @ 66 - 500 Hz
< 1.50 % @ > 500 Hz
1 The distortion specification for the MX Series is valid for pure (inductance < 12 uH) resistive load conditions and using a 30 KHz Low Pass filter on
distortion meter.
Load Regulation: 0.25 % FS @ DC - 100 Hz