Programming
148
10" Modero Touch Panels
"^" Button Commands (Cont.)
^BSF
Set the focus to
the text area.
Note: Select one button at a time (single variable text address). Do not assign a variable
text address range to set focus to multiple buttons. Only one variable text address can be
in focus at a time.
Syntax:
"'^BSF-<vt addr range>,<selection value>'"
Variable:
variable text address range = 1 - 4000.
selection value = Unselect = 0 and select = 1.
Example:
SEND_COMMAND Panel,"'^BSF-500,1'"
Sets the focus to the text area of the button.
^BSM
Submit text for
text area buttons.
This command causes the text areas to send their text as strings to the NetLinx Master.
Syntax:
"'^BSM-<vt addr range>'"
Variable:
variable text address range = 1 - 4000.
Example:
SEND_COMMAND Panel,"'^BSM-500'"
Submits the text of the text area button.
^BSO
Set the sound
played when a
button is pressed.
If the sound name is blank the sound is then cleared. If the sound name is not matched,
the button sound is not changed.
Syntax:
"'^BSO-<vt addr range>,<button states range>,<sound name>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
sound name = (blank - sound cleared, not matched - button sound not changed).
Example:
SEND_COMMAND Panel,"'^BSO-500,1&2,music.wav'"
Assigns the sound 'music.wav' to the button Off/On states.
^BVL
Log-On/Log-Off
the computer
control
connection.
Syntax:
"'^BVL-<vt addr range>,<connection>'"
Variable:
variable text address range = 1 - 4000.
connection = 0 (Log-Off connection) and 1 (Log-On connection).
Example:
SEND_COMMAND Panel,"'^BVL-500,0'"
Logs-off the computer control connection of the button.
^BVN
Set the computer
control remote
host for the
specified address.
Syntax:
SEND_COMMAND <DEV>,"'^BVN-<vt addr range>,<remote host>'"
Variables:
variable text address range = 1 - 4000.
remote host = 1 - 50 ASCII characters.
Example:
SEND_COMMAND Panel,"'^BVN-500,191.191.191.191'"
Sets the remote host to '191.191.191.191' for the specific computer control button.

Table of Contents

Other manuals for AMX NXT-CV10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX NXT-CV10 and is the answer not in the manual?

AMX NXT-CV10 Specifications

General IconGeneral
Dimensions (WxDxH)283 x 84 x 202 mm
Ethernet LAN (RJ-45) ports1
Pixel pitch0.28 x 0.28 mm
Aspect ratio16:9
Screen shapeFlat
Display diagonal10 \
Display brightness350 cd/m²
Display resolution800 x 480 pixels
Contrast ratio (typical)350:1
USB Type-A downstream ports quantity2
CertificationFCC 15 B, CE, EN60950
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 85 %
Operating relative humidity (H-H)20 - 85 %
NVIDIA G-SYNCNo
Weight and Dimensions IconWeight and Dimensions
Weight (without stand)1200 g