4-2 :CALCulate Subsystem Spectrum Analyzer Commands
4-12 PN: 10580-00319 Rev. N S412E PM
:CALCulate:LIMit:Y <y-parameter>
Title: Limit Line Y Value
Description: Sets the location of the active limit line on the y-axis at the specified
location. This moves the entire limit and moves the current active limit
point by the given value. <y-parameter> is defined in the current y-axis.
Note that this will change the Move Limit on the front panel to Limit if
it is currently set to Point. Use :CALCulate:LIMit:TYPe to set the
currently active limit line.
Parameter: <y-parameter>
Default Unit: Current y-axis unit.
Example: To move limit and set the active point to 5 dbm:
:CALCulate:LIMit:Y 5
(If y-axis unit is dBm)
:CALCulate:LIMit:Y 5dBm
Front Panel Access: Shift-6 (Limit), Limit Edit, Amplitude
:CALCulate:LIMit[:SET]:DEFault
Title: Set Default Limit
Description: Deletes all limit points for the currently active limit line and sets the
default limit line value. Note that this command will turn on the
currently selected limit line if it is not already on. The current selected
limit line can be modified by using the command
:CALCulate:LIMit:TYPe.
Example: To set the default limit line:
:CALCulate:LIMit[:SET]:DEFault
:CALCulate:LIMit:DEFault
Front Panel Access: Shift-6 (Limit), Set Default Limit