Spectrum Analyzer Commands 4-2 :CALCulate Subsystem
S412E PM PN: 10580-00319 Rev. N 4-13
:CALCulate:LIMit[:STATe] OFF|ON|0|1
:CALCulate:LIMit[:STATe]?
Title: Limit State
Description: Turns the currently selected limit line (upper or lower) ON or OFF. If
the value is set to ON or 1, the currently selected limit line is ON. If the
value is set to OFF or 0, the currently selected limit line is OFF. The
query version of the command returns a 1 if the currently selected limit
line is ON and returns a 0 if OFF. Use :CALCulate:LIMit:TYPe to set
the currently active limit line.
Parameter: OFF|ON|0|1
Parameter Type: <boolean>
Default Value: OFF
Example: To turn on the currently selected limit line:
:CALCulate:LIMit ON
:CALCulate:LIMit:STATe ON
:CALCulate:LIMit:STATe 1
To turn off the currently selected limit line:
:CALCulate:LIMit OFF
:CALCulate:LIMit:STATe 0
:CALCulate:LIMit 0
Front Panel Access: Shift-6 (Limit), On/Off
:CALCulate:MARKer:AOFF
Title: Turn All Markers Off
Description: Turns off all markers.
Front Panel Access: Marker, More, All Markers Off
:CALCulate:MARKer:PEAK:THReshold <percentage>
:CALCulate:MARKer:PEAK:THReshold?
Title: Peak Threshold
Description: Sets the peak/valley threshold as a percentage of the display.
:CALCulate:MARKer:MAXimum:LEFT and
:CALCulate:MARKer:MAXimum:RIGHt use this value to determine
whether a particular display point qualifies as a peak.
Parameter: <percentage>
Default Value: 10
Default Unit: %
Range: 0% to 100%
Front Panel Access: Marker, More Peak Options, Peak Threshold