4-2 :CALCulate Subsystem Spectrum Analyzer Commands
4-14 PN: 10580-00319 Rev. N S412E PM
:CALCulate:MARKer:TABLe[:STATe] OFF|ON|0|1
:CALCulate:MARKer:TABLe[:STATe]?
Title: Marker Table State
Description: Turns the Marker Table on or off. Setting the value to ON or 1 will turn
on the marker table. Setting the value to OFF or 0 will turn off the
marker table.
Parameter: OFF|ON|0|1
Parameter Type: <boolean>
Default Value: OFF
Example: To turn on marker table:
:CALCulate:MARKer:TABLe ON
:CALCulate:MARKer:TABLe 1
Front Panel Access: Marker, More, Marker Table
:CALCulate:MARKer{1|2|3|4|5|6}:DELTa:NOISe[:STATe]
OFF|ON|0|1
:CALCulate:MARKer{1|2|3|4|5|6}:DELTa:NOISe[:STATe]?
Title: Marker Noise
Description: Turns the delta marker noise on or off. Note that if counter marker is
set to on when setting marker noise to on, then counter marker is set to
off. This command is not valid in zero span. The query version of this
command returns a 1 if the specified delta marker is noise marker and
returns a 0 if not.
Parameter: OFF|ON|0|1
Parameter Type: <boolean>
Default Value: OFF
Example: To turn on marker noise for delta marker #1:
:CALCulate:MARKer1:DELTa:NOISe ON
:CALCulate:MARKer1:DELTa:NOISe 1
:CALCulate:MARKer:DELTa:NOISe 1
:CALCulate:MARKer:DELTa:NOISe:STATe ON
To turn on marker noise for delta marker #2:
:CALCulate:MARKer2:DELTa:NOISe ON
:CALCulate:MARKer2:DELTa:NOISe 1
:CALCulate:MARKer2:DELTa:NOISe:STATe ON
To turn off marker noise #5:
:CALCulate:MARKer5:DELTa:NOISe OFF
:CALCulate:MARKer5:DELTa:NOISe 0
:CALCulate:MARKer5:DELTa:NOISe:STATe OFF
Front Panel Access: Marker, More, Marker Noise