16-13 [:SENSe] Subsystem NBFM Commands
16-52 PN: 10580-00319 Rev. N S412E PM
[:SENSe]:POWer[:RF]:RANGe[:IMMediate]
Description: Turns off auto ranging and adjusts the receiver reference level once.
In NBFM Analyzer measurement, this command adjusts the receiver
reference level of the spectrum graph.
Cmd Parameters: NA
Query Parameters: NA
Range: NA
Default Value: NA
Default Unit: NA
Example: To adjust range:
:POWer:RANGe
Front Panel Access: Amplitude, Adjust Rx Range
[:SENSe]:POWer[:RF]:RANGe:AUTO OFF|ON|0|1
[:SENSe]:POWer[:RF]:RANGe:AUTO?
Description: Turns auto range for the receiver on or off. When auto range is on, the
reference level is automatically adjusted to the proper value to show the
trace on the screen. If the auto ranging is turned off, the reference level
will not adjust according to where the trace is. In NBFM Analyzer
measurement, this command adjusts the reference level of the spectrum
graph.
Cmd Parameters: OFF|ON|0|1
Query Parameters: NA
Range: OFF|ON|0|1
Default Value: ON or 1
Default Unit: NA
Example: To turn auto ranging off:
:POWer:RANGe:AUTO OFF
Front Panel Access: Amplitude, Auto Rx Range