EasyManua.ls Logo

Anritsu LMR Master S412E - Page 658

Anritsu LMR Master S412E
704 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18-7 [:SENSe] Subsystem AM/FM/PM Commands
18-16 PN: 10580-00319 Rev. N S412E PM
[:SENSe]:AFPanalyzer:SWEep:TIME <time>
[:SENSe]:AFPanalyzer:SWEep:TIME?
Title: Audio Waveform sweep time
Description: Sets the audio waveform sweep time in the audio waveform view.
Parameter: <time>
Default Unit: Secs
Range: 50 µs to 50 ms.
Front Panel Access: Shift-4 (Measure), Audio Waveform, Sweep Time
[:SENSe]:AFPanalyzer:SUMMary:DATA?
Title: Summary data
Description: This query returns the measurment values in the Summary view. The
order of the values are as follows:
<demod type> (AM|FM|PM), <RMS Deviation> in % or Hz or Rad
depending on the demod type, <Peak+ Deviation> in % or Hz or Rad
depending on the demod type, <Peak-Dev> in % or Hz or Rad depending
on the demod type,
<Peak-Peak/2 Dev> in % or Hz or Rad depending on the demod type,
<carrier power> in dBm, <carrier freq> in Hz, <Occ BW> in Hz,
<Modulation rate> in Hz, <SINAD> in dB, <THD> in % and
<Distortion> in %. All values are comma separated.
Front Panel Access: Shift-4 (Measure), Summary.
[:SENSe]:FREQuency:CENTer <freq>
[:SENSe]:FREQuency:CENTer?
Title: Center Frequency
Description: Sets the center frequency. Note that changing the value of the center
frequency may also change the value of the span.
Parameter: <freq>
Default Unit: Hz
Front Panel Access: Freq, Center Freq
[:SENSe]:FREQuency:SIGStandard:CHANnel <number>
[:SENSe]:FREQuency:SIGStandard:CHANnel?
Title: Channel Selection
Description: Sets the channel number for the selected signal standard.
Parameter: <number>
Front Panel Access: Freq, Channel