5-36
ERRINT (Error Add Interval Command/Query)
Function
Sets error addition interval.
Header Program command Query Response
ERRINT ERRINT n ERRINT? ERRINT n
Value of n
0: None
1: Manual
2: 1
10
–2
3: 1
10
–3
4: 1
10
–4
5: 1
10
–5
6: 1
10
–6
7: 1
10
–7
Example use
ERRINT 0
ERRINT?
Example response message
ERRINT 1
SYNC (Auto Sync Command/Query)
Function
Sets on/off of Auto Sync.
Header Program command Query Response
SYNC SYNC n SYNC? SYNC n
Value of n
0: OFF
1: ON
Example use
SYNC 0
SYNC?
Example response message
SYNC 0