5.5 Device Message Details
5-39
5.5.4 Measurement time/count parameter-related messages
MEAS (Measure Select Command/Query)
Function
Select measurement method.
Header Program command Query Response
MEAS MEAS n MEAS? MEAS n
Value of n
0: None
1: Time
2: Count
Example use
MEAS 0
MEAS?
Example response message
MEAS 0
MEASTIME (Measure Time Command/Query)
Function
Sets measurement time.
Header Program command Query Response
MEASTIME MEASTIME n1,n2,n3 MEASTIME? MEASTIME n1,n2,n3
Value of n1
<Hour> 0 to 999
Value of n2
<Minute> 0 to 59
Value of n3
<Second> 0 to 59
Example use
MEASTIME 0,0,1
MEASTIME?
Example response message
MEASTIME 0,10,0