Anybus Module Objects 153 (258)
Command Details: Set_IO_Config_String
Category
Extended
Details
Command Code 11h
Valid for: Object
Description
This command is sent from the host application when there is a need to change the default configuration of
the safety inputs and outputs. This string is used by networks where there are no other means (e.g. PLC or
some other tool) to provide the configuration to the safety module. Consult the specification of the safety mod-
ule for more information. The byte string passed is generated by HMS and need to be passed unmodified us-
ing this command.
Information about this string is located in the specification of the safety module to which the string shall be
sent.
Command Details
Field Contents
CmdExt[0] (not used)
CmdExt[1]
Data[0... n] Data (byte string)
The data consists of an IO configuration string, where the data format depends on the safety network.
Response Details
(no data)