Host Application Objects 180 (258)
Instance Attributes (Instance #1 - #8)
# Name Access Data Type Description
1 ModeAttributes Get BITS16 Bit 0: Meaning:
0: Only static time and energy values are available
(Value of bit 0 attribute is not implemented)
1: Dynamic time and energy values are available
Bit 1-15: Reserved
2 TimeMinPause Get UINT32 Minimum pause time in milliseconds. (t
pause
)
If the value is infinite, or unknown, the maximum value
0xFFFFFFFF shall be used.
3 TimeToPause Get UINT32 Maximum time to go to this Energy saving mode.(ms, t
off
)
If the value is infinite, or unknown, the maximum value
0xFFFFFFFF shall be used.
4 TimeToOperate Get UINT32 Maximum time needed to go to the “Ready to operate” mode.
(ms, t
on
)
If the value is infinite, or unknown, the maximum value
0xFFFFFFFF shall be used.
5
TimeMinLengthOf-
Stay
Get UINT32 The minimum time that the device must stay in this mode. In
milliseconds.(ms, t
off_min
)
If the value is infinite, or unknown, the maximum value
0xFFFFFFFF shall be used.
6 TimeMaxLengthOf-
Stay
Get UINT32 Maximum time that is allowed to stay in this mode. In
milliseconds.
If no maximum value is available or if not implemented, the max-
imum value FFFFFFFFh shall be used.
7
ModePowerCon-
sumption
Get FLOAT Amount of power consumed in this mode. (kW)
If the value is undefined the value 0.0 shall be used.
8 EnergyConsumption-
ToPause
Get FLOAT Amount of energy required to go to this mode. (kWh)
If the value is undefined the value 0.0 shall be used.
9 EnergyConsumption-
ToOperate
Get FLOAT Amount of energy required to go to the “Ready to operate” mode
from this mode. (kWh)
If the value is undefined the value 0.0 shall be used.
10 Availability Get BOOL Indicates if this energy saving mode is available given the cur-
rent device state.
Not used for PROFINET.
False Not available
True Available (Value if attribute not implemented)
11 Power Consumption Get UINT32 Indicates the power consumption of the device when in this
state.
Not used for PROFINET.
Anybus
®
CompactCom
40 PROFINET IRT Network Guide SCM-1202-023 EN 1.8