Host Application Objects 182 (258)
Command Details: End_Pause
Details
Command Code 11h
Valid for: Object
Description
This command is sent to the host application when the system wants to return the system from a pause mode
back to “Ready to operate” mode. In the response message the number of milliseconds to actualize the
switch is returned.
Command Details
(none)
Response Details
Field Contents Comments
Data[0] Time To Operate (low word, low byte) Time needed to switch to “Ready to operate”
Data[1] Time To Operate (low word, high byte)
Data[2] Time To Operate (high word, low byte)
Data[3] Time To Operate (high word, high byte)
If the application is unable to end the pause it shall return the error code in the table below.
# Error code Description
0x0D Invalid state Given the state of the device, it is currently not possible to end the pause