JSON 72 (258)
update.json
POST adi/update.json
Form data:
inst=<instance>&value=<data>[&elem=<element>][&callback=<function>]
Updates the value attribute of an ADI.
Request data:
Name Data Type Description
inst Number Instance number of the ADI
value String Value to set.
If the value attribute is a number it shall be hes formatted, see
Hex Format Explained, p. 83 for more information.
elem Number Optional.
If specified only a single element of the ADI value is set. Then
<data> shall only contain the value of the specified <element>.
callback String Optional.
A callback function for JSONP output.
Response data:
Name Data Type Note
result Number 0 = success
The Anybus CompactCom error codes are used. Please see the
Anybus CompactCom 40 Software Design Guide.
{
"result" : 0
}
Anybus
®
CompactCom
40 PROFINET IRT Network Guide SCM-1202-023 EN 1.8

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anybus CompactCom 40 and is the answer not in the manual?

Anybus CompactCom 40 Specifications