EasyManua.ls Logo

ARS Flexibowl 200 - Troubleshooting

Default Icon
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 7 - Maintenance 91
Instructions for use and warnings
7.4 Troubleshooting
No.
Problem
Solution
1
The status LED (Ready/Fault) is red.
If the Flexibow
is working, check operation of the
LED or the mechanical relay inside the interface.
Check the condition of the fuse inside the power input
module and replace it if necessary.
Check that no parts prevent free movement of the
Rotary Disc
Note: if the problem persists, contact ARS S.r.l.
2
The Flexibowl® vibrates/oscillates excessively.
Check that the screws are tightened properly.
Check if the load of Flexibowl® is within the permitted
parameters based on the model.
Try to decrease the movement parameters
(acceleration, deceleration, speed)
Note: if the problem persists, contact ARS S.r.l.
3
The status LED (Ready/Fault) is off.
Check that the power supply is correct and
working.
Check the condition of the fuses inside the
interface board and replace it if necessary.
Note: if the problem persists, contact ARS S.r.l.
4
The Flip does not work.
Check that the screen displays the correct pressure
Check the air pressure inside the air supply system
control panel.
Check the condition of the pressure regulator.
Check that the power supply is correct and
working.
Check that the valves work properly.
Make sure the valve relay inside the interface is
working properly.
Check the condition of the fuse inside the interface
and replace it if necessary.
Note: if the problem persists, contact ARS S.r.l.
5
The Air Blow does not work.
Check that the screen displays the correct pressure
Check the air pressure inside the air supply system
control panel.
Check the condition of the pressure regulator.
Check that the power supply is correct and
working.
Check that the valves work properly.
Make sure the valve relay inside the interface is
working properly.
Check the condition of the fuse inside the interface
and replace it if necessary.
Note: if the problem persists, contact ARS S.r.l.

Table of Contents