CHAPTER 7 - Maintenance 91
Instructions for use and warnings
The status LED (Ready/Fault) is red.
• If the Flexibowl®
is working, check operation of the
LED or the mechanical relay inside the interface.
• Check the condition of the fuse inside the power input
module and replace it if necessary.
• Check that no parts prevent free movement of the
Rotary Disc
Note: if the problem persists, contact ARS S.r.l.
The Flexibowl® vibrates/oscillates excessively.
• Check that the screws are tightened properly.
• Check if the load of Flexibowl® is within the permitted
parameters based on the model.
• Try to decrease the movement parameters
(acceleration, deceleration, speed)
Note: if the problem persists, contact ARS S.r.l.
The status LED (Ready/Fault) is off.
• Check that the power supply is correct and
working.
• Check the condition of the fuses inside the
interface board and replace it if necessary.
Note: if the problem persists, contact ARS S.r.l.
• Check that the screen displays the correct pressure
• Check the air pressure inside the air supply system
control panel.
• Check the condition of the pressure regulator.
• Check that the power supply is correct and
working.
• Check that the valves work properly.
• Make sure the valve relay inside the interface is
working properly.
• Check the condition of the fuse inside the interface
and replace it if necessary.
Note: if the problem persists, contact ARS S.r.l.
The Air Blow does not work.
• Check that the screen displays the correct pressure
• Check the air pressure inside the air supply system
control panel.
• Check the condition of the pressure regulator.
• Check that the power supply is correct and
working.
• Check that the valves work properly.
• Make sure the valve relay inside the interface is
working properly.
• Check the condition of the fuse inside the interface
and replace it if necessary.
Note: if the problem persists, contact ARS S.r.l.