A selection of “Radius” style blades is also available. These also come with 20 or 30 degree cutting
edges.
The “Radius” style blades will give a fuller cut around the circumference of the cable.
MAINTENANCE
PREVENTIVE MAINTENANCE
DailyMaintenance
The CS 326 B has been designed to be as maintenance free as possible. Daily care consists of
keeping the machine clean and free of stripping debris. Blade and feed belt condition should be
monitored daily and replaced as needed.
SemiAnnualMaintenance
Semi-annually the cutterhead ballscrew and the feed system tensioning worm gear, pinion, chains and
sprockets should be wiped clean and greased with ARTOS BALLSCREW GREASE part number
916-450.
Check belt tension and adjust as needed. See “Belt Adjustments”. (See page Error! Bookmark not
defined.)
Clean any debris from inside of cabinet.
Computertomachinecontrollercommunications
This section is to determine why the computer is not communicating with the CS326 CPU board. The
problem may show up in one of the three following ways.
1. The message Port [1] not available. This means that the computer either has a problem with the COM
port [1] or there is another program that is using this port. The CS326 software can be configured to
use a different COM port for testing. Edit the file Program Files(x86)/ Artos
Engineering/CS326GUI/config/mtxcfg.xml. After saving the file, restart the CS326 software. If
Programs Files (x86) does not exist then go to Program Files. Remember to make sure the serial cable
from the machine is plugged into the right port on the computer.