Environmental
Uplink port module
Operating
temperature:
JL319A, JL320A, JL321A, JL322A, JL323A, R0M67A
• 0°C to 55°C (32°F to 131°F) up to 5,000 ft.
• 0°C to 50°C (32°F to 122°F) up to 10,000 ft. (Reduce 1°C for
every 1,000 ft above 5,000 ft.)
NOTE: If any of the following transceivers are
installed in the switch, then the maximum operating
temperature for an Aruba 2930M switch is 50°C
(122°F):
• J9150A HPE X132 10G SFP+ LC SR Transceiver
• J9151A HPE X132 10G SFP+ LC LR Transceiver
• J9152A HPE X132 10G SFP+ LC LRM
Transceiver
• J9153A HPE X132 10G SFP+ LC ER Transceiver
• JH231A HPE X142 40G QSFP+ MPO SR4
Transceiver
• JH232A HPE X142 40G QSFP+ LC LR4 SM
Transceiver
• JH233A HPE X142 40G QSFP+ MPO eSR4
Transceiver
NOTE: JL324A and R0M68A have reduced
maximum operating temperature restrictions:
• 32°F to 113°F (0°C to 45°C) up to 5,000 ft.
• 32°F to 104°F (0°C to 40°C) up to 10,000 ft.
(Reduce 1 degree C for every 1,000 ft from 5,000
ft to 10,000 ft.)
Relative humidity: 15% to 95% at 40°C (104°F) noncondensing to 10,000 ft.
Nonoperating
temperature:
-40°C to 70°C (-40°F to 158°F) up to 15,000 ft
Nonoperating
relative humidity:
15% to 90% at 65°C (149°F) (noncondensing up to 15,000 ft.
Maximum operating
altitude:
3.0 km (10,000 ft)
Nonoperating
altitude:
4.6 km (15,000 ft)
Chapter 7 Specifications 83