Variable Value
unit Specifies the log messages for a certain
unit.
Configuring System Logging using ACLI
Configure the system settings for the system event log.
Procedure
1. Log on to ACLI in Global Configuration command mode.
2. At the command prompt, enter the following command:
[no] [default] logging [enable|disable] [level critical|
serious| informational|none] [nv-level critical|serious|
none] remote [address|enable|level] volatile [latch|
overwrite]
Variable definitions
The following table describes the parameters for the logging command.
Variable
Value
enable|disable Enables or disables the event log
DEFAULT: Enabled
level critical|serious|informational|none Specifies the level of logging stored in
DRAM.
nv-level critical|serious|none Specifies the level of logging stored in
NVRAM.
remote Configures remote logging parameters:
• Address: configure remote syslog address
• Enable: enable remote logging
• Level: configure remote logging level
volatile Configures options for logging to DRAM.
• Latch: latch DRAM log after it is full
• Overwrite: overwrite DRAM log after it is
full
System logs using ACLI
Configuration — System Monitoring March 2013 29