Variable definitions
The following table describes the parameters for the show rmon ethernet statistics
port command.
Variable Value
LINE Specifies a list of ports
Configuring RMON Alarms using ACLI
Set RMON alarms and thresholds.
Procedure
1. Log on to ACLI in Global Configuration command mode.
2. At the command prompt, enter the following command:
rmon alarm <1-65535> <WORD> <1-2147483647> {absolute | delta}
rising-threshold <-2147483648-2147483647> [<1-65535>]
falling-threshold <-2147483648-2147483647> [<1-65535>]
[owner <LINE>]
Variable definitions
The following table describes the parameters for the rmon alarm command.
Variable
Value
<1–65535> Specifies the unique index for the alarm entry
<WORD> Specifies the MIB object to be monitored.
This is an object identifier, and for most
available objects, an English name can be
used
<1–2147483647> Specifies the sampling interval, in seconds
absolute Specifies absolute values (value of the MIB
object is compared directly with thresholds)
RMON using ACLI
74 Configuration — System Monitoring March 2013
Comments? infodev@avaya.com