Name Description
oriented or fixed-length interfaces, the
number of outbound transmission units that
cannot be transmitted because of errors.
InUnknownProtos For packet-oriented interfaces, the number
of packets received through the interface that
are discarded because of an unknown or
unsupported protocol. For character-
oriented or fixed-length interfaces that
support protocol multiplexing, the number of
transmission units received through the
interface that are discarded because of an
unknown or unsupported protocol. For any
interface that does not support protocol
multiplexing, this counter is always zero.
Graphing Ethernet error statistics using EDM
Use this procedure to view and graph Ethernet error statistics.
Procedure
1. On the Device Physical View, click on a port.
2. In the navigation tree, double-click Graph.
3. In the Graph tree, double-click Port.
4. In the work area, click the Ethernet Errors tab.
5. Click a row of data to graph under a column heading.
6. On the toolbar, click the Poll Interval and select an interval.
7. On the toolbar, you can reset the data by clicking Clear Counters.
8. On the toolbar, click a graph type.
Ethernet Errors tab field descriptions
The following table describes the fields on the Ethernet Errors tab.
Name
Description
AlignmentErrors Specifies a count of frames received on a
particular interface that are not an integral
number of octets in length and do not pass
Displaying port statistics using EDM
Configuration — System Monitoring March 2013 65