Enabling Ethernet statistics gathering using EDM
Use this procedure to use RMON to gather Ethernet statistics.
Procedure
1. In the navigation tree, double-click Rmon.
2. In the Rmon tree, double-click Control.
3. In the work area, click the Ether Stats tab.
4. On the toolbar, click Insert to open the Insert Ether Stats dialog box.
5. In the Index box, type the index number of click the ellipsis (...) to select an index
number from the list.
After you enter the port number, EDM assigns an index number.
6. In the Port box, type the port number or click the ellipsis (...) to select a port from
the list.
7. In the Owner box, type the owner information.
8. Click Insert.
Ether Stats tab field descriptions
The following table describes the fields on the Ether Stats tab.
Name
Description
Index Specifies a unique value assigned to each
interface. An index identifies an entry in a
table.
Port Specifies any Ethernet interface on the
device.
Owner Specifies the network management system
which created this entity.
Disabling Ethernet statistics gathering using EDM
Use this procedure to disable Ethernet statistics that you have set.
Ethernet statistics gathering using EDM
Configuration — System Monitoring March 2013 89