Variable definitions
The following table defines parameters that you can enter with the energy-saver schedule
{weekday|weekend|monday|tuesday |wednesday|thursday|friday|saturday|
sunday} <hh:mm> {activate|deactivate} command.
Variable Value
<activate> Specifies the AES on time.
<deactivate> Specifies the AES off time.
monday|tuesday|wednesday |thursday|friday|
saturday| sunday
Configures AES scheduling for a specific day.
<hh:mm> Specifies the scheduled AES start time (hour and
minutes).
weekday Configures AES scheduling for all weekdays.
weekend Configures AES scheduling for Saturday and
Sunday.
Disabling AES scheduling using ACLI
Use the following procedure to discontinue using an on and off time interval for the switch to enter
lower power states.
Before you begin
• Disable AES globally.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. Disable AES scheduling.
no energy-saver schedule
Variable definitions
The following table defines optional parameters that you can enter after the no energy-saver
schedule command.
Variable Value
monday|tuesday|wednesday |thursday|friday|
saturday|sunday
Disables AES scheduling for a specific day.
<hh:mm> Specifies the scheduled time to disable AES (hour
and minutes).
weekday Disables AES scheduling for all weekdays.
weekend Disables AES scheduling for Saturday and Sunday.
Configuring the switch using ACLI
July 2015 Getting Started with Avaya ERS 3500 Series 87