EasyManua.ls Logo

Baumer EA Series - Via Rotary Switches

Default Icon
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Baumer_EAx_EtherNetIP_EN_MNL 14/81 www.baumer.com
02.20
4.2. Via Rotary Switches
If the value read from the rotary switches is unequal to 00 the IP address is "192.168.1.XY". The value of XY
is calculated as follows.
X
Y
Value of rotary switch 1
Value of rotary switch 2
Open the screw cap to get access to the rotary switches. Set the rotary switches to the desired IP address.
An example is shown below.
In this example the rotary switches are set to X=0x04 and Y=0x02 which results to:
4 * 16 + 2 = 66 -> The IP address is set to 192.168.1.66.
In the following chapters the details about the functionality of the device depending on the value of the rotary
switches are described.
Generally the formula for the
value of the 4th octet (byte)
of the IP address is:
X * 16 + Y

Table of Contents

Related product manuals