EasyManuals Logo

Baumer EA Series User Manual

Default Icon
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
Baumer_EAx_EtherNetIP_EN_MNL 54/81 www.baumer.com
02.20
7.12. Connection Manager Object (0x06)
The Connection Manager Class allocates and manages the internal resources associated with both I/O and
Explicit Messaging Connections. The specific instance generated by the Connection Manager Class is
referred to as a Connection Instance or a Connection Object.
7.12.1. Class Services
Service Code
Service Name
Description
0x0E
Get_Attribute_Single
Returns the contents of the
specified attribute
7.12.2. Class Attributes
Attribute
ID
Access
Rule
Name
Data
Type
Description
Semantics of
Values
Value
1
Get
Revision
UINT
Revision of this
object
The current value
assigned to this
attribute is one
(01). If updates that
require an increase
in this value are
made, then the
value of this
attribute increases
by 1.
1
2
Get
Max
Instance
UINT
Maximum instance
number of an
object currently
created in this class
level of the device.
The largest
instance number of
a created object at
this class hierarchy
level.
1
7.12.3. Instance Services
Instance services for the connection manager object are not supported.
7.12.4. Instance Attributes
Instance attributes for the connection manager object are not supported.