Baumer_EAx_EtherNetIP_EN_MNL 22/81 www.baumer.com
02.20
5.7. Configuration data
The layout of the configuration data is described in the following table.
Assembly Instance 105, Configuration Data, Length: 32 bytes
Byte N
umber
Position Sensor
Object,
Instance Attribute
Description
Default values of
encoder variant
ST13MT16
Default values of
encoder variant
ST18MT13
Default values of
encoder variant
ST14MT16
Byte 0
12
Direction Counting Toggle
0
0
0
Byte 1
14
Scaling Function Control
1
1
1
Byte 2
16
Measuring Units per Span
0x2000
0x40000
0x4000
Byte 3
Byte 4
Byte 5
Byte 6
17
Total Measuring Range
0x20000000
0x80000000
0x40000000
Byte 7
Byte 8
Byte 9
Byte 10
25
Velocity Format
0x1F0F
0x1F0F
0x1F0F
Byte 11
Byte 12
26
Velocity Resolution
1
1
1
Byte 13
Byte 14
Byte 15
Byte 16
100
Velocity Sample Rate
16
16
16
Byte 17
101
Velocity Filter
5
5
5
Byte 18
102
Gear Factor Activation
0
0
0
Byte 19
Byte 20
103
Gear Factor Numerator
0x2000
0x1000
0x4000
Byte 21
Byte 22
Byte 23
Byte 24
104
Gear Factor Denominator
1
1
1
Byte 25
Byte 26
Byte 27
Byte 28
107
Preset Request Value
0
0
0
Byte 29
Byte 30
Byte 31
For changing values of any attribute via explicit messages see Parametrierung per Acyclic Services.