51
20 08 CONTESSA
DRIVING & SAFETY — 2
To Disarm the System:
Press the Unlock button on the key fob, or
enter the unlock code on the key pad, to disarm
the security system. The dash-mounted LED
will turn off and the system will beep twice
when disarmed.
Alarm:
Starting the engine, breaking bedroom glass
and/or opening the entry door, bay doors with
pin switches or a bedroom window will sound
alarm. The siren will sound and the parking
lights and headlights will ash for 30 seconds.
The LED on the dash willash continuously.
To Turn Off Alarm:
Press the Lock or Unlock
button on the key fob, or
turn the ignition on and
hold the push button
located on the dash in
for ve seconds.
Sound and Window Sensors:
Two sound sensors are used to detect impact
noise (repetitive or single heavy impact) and
glass breakage. Sound sensors are located in the
galley and in the bedroom. Window sensors are
located on the bedroom windows only.
These sensors detect window screen
movement. If the screen is opened more than
½", the alarm will sound when the security
system is activated. Each sensor is equipped
with a pair of replaceable batteries. Test the
sound and window sensors monthly.
Testing Sound Sensor:
Clap hands loudly next to sensor. LED
should briey illuminate twice.
Testing Window Sensor:
Momentarily press on housing next to
LED to briey illuminate.
SMOKE DETECTOR
Statistics show that most re casualties are
not caused by direct ame, but by less visible
smoke (products of combustion). The smoke
detector will automatically return from alarm to
normal state when the reason for activation, the
presence of smoke, is completely removed.
Fires are commonly caused by smoking
in bed, leaving children unattended or using
ammable cleaning uids. Please be safety
conscious and avoid unnecessary risk.
WARNING:
There is no way to ensure against
injury or loss of life in a fire; however,
the smoke detector is intended to help
reduce the risk of tragedy. Additional
smoke detectors may help reduce the
risk. Proper use and care of the smoke
detector could save lives.
Operation
When a 9 Volt DC battery is correctly
connected, the LED will ash every minute
and a loud alarm will sound when a product of
combustion is sensed.
NOTE:
The unit will not operate without a
battery. A battery flag will pop up
preventing the unit from being installed
to the mounting bracket without a
battery. Carbon zinc batteries average a
service life of one year. Alkaline batteries
average a service life of one to two years.
Testing
Simply press the test button on the smoke
alarm cover for approximately three seconds.
The alarm will sound if all electronic circuitry,
horn and battery are properly working. The
smoke alarm should be tested at least once a
week when the motorhome is in use, prior to
each trip and when the motorhome has been
in storage. When testing the smoke alarm it is
advised to stand at arm’s length.