Diagmessages of module AxisMain
Multi axis servo system - AX8000108
Version: 1.1
6.9 3180, Phase failure motor
The drive software detected an phase failure at the motor side. Please check wiring.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
3180 12672
Class Type
Error Motor connection error
Standard Reaction Reset
Shorted coils brake Execute Reset-Command (Fault reset).
Possible Causes Solutions
A power wire is not connected properly to the hybrid
motor connector.
Check the power connections to the hybrid motor
connector.
The hybrid motor connector seems not to be plugged
in properly.
Check if the hybrid motor connector is plugged in
properly.
A power wire in the motor cable is broken. Check the power wires in the motor cable.
Internal: 0x3180, Phase failure motor