Diagmessages of module PowerGridConnection
Multi axis servo system - AX8000 229
Version: 1.1
17 Diagmessages of module PowerGridConnection
17.1 FFFF, Internal Error, Additional Errorcode
Internal Error
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
FFFF 65535
Class Type
Error Error
Standard Reaction Reset
Closed loop ramp Execute Reset-Command (Fault reset).
Possible Causes Solutions
An unknown hard- or software error has occurred. Disconnect the power supply module from the mains
(including the 24 V power supply) and start a new
attempt. If this error occurs repeatedly, please call
the Beckhoff support that is responsible for you.
Internal: 0xFFFF, Internal Error, Additional Errorcode 0x%x