Diagmessages of module OCT rotary (Hiperface DSL)
Multi axis servo system - AX8000 209
Version: 1.1
14.9 7387, HpfDsl: The encoder doesn't meet the specified
policies.
The encoder doesn't meet the specified policies. See objects 'encoder policies' and 'encoder info'.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
7387 29575
Class Type
Error Feedback error
Standard Reaction Reset
Closed loop ramp Execute Reset-Command (Fault reset).
Possible Causes Solutions
No physical encoder connection. Check and fix the encoder connection.
Internal: 0x7387, HpfDsl: The encoder doesn't meet the specified policies. Resolutionpolicy=%d [Encoder=
%d, Requirement=%d], Rangepolicy=%d [Encoder=%d, Requirement=%d]