Diagmessages of module AxisMain
Multi axis servo system - AX8000 145
Version: 1.1
6.46 63A7, The range of the Position range limit is below the
minimum accepted value
The range of the Position range limit (Object 0x6096 ChA or 0x6896 ChB) is below the minimum accepted
value. The Range is calculated 'max limit' - 'min limit' + 1 and has to be positive.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
63A7 25511
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
The range of the Position range limit (Object 0x6096
ChA or 0x6896 ChB) is below the minimum accepted
value. The Range is calculated 'max limit' - 'min limit'
+ 1 and has to be positive.
Please check the min and max value of the position
range limit.
Internal: 0x63A7, The range %u of the Position range limit is below the minimum accepted value of %u.