Diagmessages of module SyncServoMotor
Multi axis servo system - AX8000216
Version: 1.1
16.4 638B, Parameter Torque Current curve: Unable to
calculate Torque Current curve.
The characteristic is not monotonically increasing or not in the right working range.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
638B 25483
Class Type
Error Error
Standard Reaction Reset
Shorted coils brake Execute Reset-Command (Fault reset).
Possible Causes Solutions
The characteristic is not monotonically increasing or
not in the right working range.
Check the configured motor and the torque current
curve.