Standard-Messages
Multi axis servo system - AX800070
Version: 1.1
3.56 A035, DynPdo Mapping Warning: Unable to map Object
(no Mappings left).
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
A035 41013
Class Type
Warning Warning
Standard Reaction Reset
No Warning: No reset required.
Possible Causes Solutions
A mapping Parameter is not supported of this Device. Please check, your mapping Configuration.
Internal: 0xA035, DynPdo Mapping Warning: Unable to map Object 0x%x/%x.(no Mappings left)
(SyncManager %u)