Diagmessages of module SimulationRotary
Multi axis servo system - AX8000 211
Version: 1.1
15 Diagmessages of module SimulationRotary
15.1 63AC, Encoder simulation is not supported for the
selected motor type
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
63AC 25516
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
The selected module in the motor slot is not
supported for encoder simulation.
Select another encoder type or no encoder.
Internal: 0x63AC, Encoder simulation is not supported for the selected motor type. (ModuleIdent 0x%X)