6.23 6390, Factor Group Parameters: Feed constant illegal
feed
The actual combination of the factor group Parameters is not allowed for this Device.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
6390 25488
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
The feed constant - feed contains an illegal value
(Object 0x6092/1 ChA or 0x6892/1 ChB).
Please use a 2
x
value (x from 16 to 28) for rotary
encoders and a 10
x
value (x from 0 to 9) for linear
encoders.
Internal: 0x6390, Factor Group Parameters: Feed constant illegal feed