Page #142 background image
Diagmessages of module AxisMain
Multi axis servo system - AX8000142
Version: 1.1
6.43 63A4, Offset position actual value: No position offset
existing in source 'drive memory'
There is no primary position offset stored, for the selected source 'drive memory'.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
63A4 25508
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
A position offset should used in the position control
loop, but no position offset has been saved.
Calibrate the axis and save the new position offset.
Internal: 0x63A4, Offset position actual value: No position offset existing in source 'drive memory'