Standard-Messages
Multi axis servo system - AX800028
Version: 1.1
3.14 5594, Simulating persistent data features.
If you see this Message, all persistent Data will start with zero Values on PowerOn.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
5594 21908
Class Type
Warning Warning
Standard Reaction Reset
No Warning: No reset required.
Possible Causes Solutions
Persistent Memory is not supported in the early
Hardware Versions.
Internal: 0x5594, Simulating persistent data features.