Diagmessages of module AxisMain
Multi axis servo system - AX8000 133
Version: 1.1
6.34 639B, additional Factor Group Parameters: Position
encoder resolution illegal motor revolutions
The actual combination of the factor group Parameters is not allowed for this Device.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
639B 25499
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
The additional position encoder resolution - motor
revolutions contains an illegal value (Object
0x60EB/1 ChA or 0x68EB/1 ChB).
Please compare it to your encoder values.
Internal: 0x639B, additional Factor Group Parameters: Position encoder resolution illegal motor revolutions