Diagmessages of module AxisMain
Multi axis servo system - AX8000 141
Version: 1.1
6.42 63A3, Offset additional position actual value: No
position offset existing in source 'encoder memory'
There is no secondary position offset stored, for the selected source 'encoder memory'.
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
63A3 25507
Class Type
Error Error
Standard Reaction Reset
Axis is inoperable Execute Reset-Command (Fault reset).
Possible Causes Solutions
A position offset should used in the position control
loop, but no position offset has been saved.
Calibrate the axis and save the new position offset.
Internal: 0x63A3, Offset additional position actual value: No position offset existing in source 'encoder
memory'