Standard-Messages
Multi axis servo system - AX800044
Version: 1.1
3.30 8180, System restart or sync lost
Diagnostic Code (Hex.) Diagnostic Code (Dez.)
8180 33152
Class Type
Error Error
Standard Reaction Reset
Closed loop ramp Execute Reset-Command (Fault reset).
Possible Causes Solutions
The Slave has received no ProcessData for more
than one EtherCAT Cycle.
Check the realtime Tasks of your EtherCAT Master.
Internal: 0x8180, System restart or sync lost