Faults | MT ZERO 6 LCD | 117
Err Possible causes Remedy
Err 29 The rim-width gauge for the distance measurement is not in
the rest position.
R Ensure that the rim-width gauge is in the rest position.
R Check the analog value a5.
R Repeat the procedure for calibrating the rim-width
gauge.
Err 30 Calibration plate is not mounted on flange or not mounted
correctly.
R Ensure that the calibration plate is mounted on the
flange correctly.
R Repeat calibration.
If the error message persists, contact customer service.
Err 32 Pedal has been pressed. Avoid pressing the pedal during the measuring cycle.
Err 42 Pneumatic flange is open. Close the pneumatic flange by pressing the pedal.
Err 48 Time for obtaining the wheel width data by the
measurement sensor expired.
Repeat measurement.
Err 49 Wheel cover not opened completely Open wheel cover completely.
EEE EEE Two keys pressed simultaneously. Always press only one key at a time.
If the error message persists, contact customer service.