Field Value
ACCESS_REJECT Server -> Client
If the information contained in the ACCESS_REQUEST does
not correspond to the information in the user database of the
RADIUS server, it sends an ACCESS_REJECT to reject the
connection.
ACCOUNTING_START Client -> Server
If a RADIUS server is used for accounting, your device sends
an accounting message to the RADIUS server at the start of
each connection.
ACCOUNTING_STOP Client -> Server
If a RADIUS server is used for accounting, your device sends
an accounting message to the RADIUS server at the end of
each connection.
A list of all entered RADIUS servers is displayed in the System Management->Remote
Authentication->RADIUS menu.
7.5.1.1 Edit or New
Choose the icon to edit existing entries. Choose the New button to add RADIUS serv-
ers.